Telefax : +91-22-25452111
  Mobile No : 9967837920
  Email:sales@bioline.in
  Main Categories
   
 
Untitled Document
   Biosafety Cabinet
 
 
Blood Bank Equipments
 
 
 
 
 
 

 

   

Click To Enlarge

Biosafety Cabinet

Biosafety cabinet are applied in microorganism, biology engine &some place which have rigorous requirement to working environment. This kind of cabinet can prevent efficiently pathogenic microorganism, microorganism, genes 7etc. from diffusing. Also the cabinet can obstruct the contamination to operator from these materials. So the cabinet can supply non –bacteria & non –dust working condition for medical treatment, medical producing & science research.

 

 

Model

HR40-IIA2

HR60-IIA2

HR40-IIB2

Cleanliness

 CLASS 100@>0.5*m

 CLASS 100@>0.5*m

 CLASS 100@>0.5*m

Down flow air velocity

 0.32+-0.015m/s

 0.32+-0.015m/s

 0.32+-0.015m/s

Inflow air velocity

 0.62+-0.015m/s

 0.62+-0.015m/s

 0.62+-0.015m/s

Illumination

 >900LX

 >900LX 

 >900LX

Noise

 <58db(A)

 <58db(A) 

 <64db(A)

UV light

 >30w

 >30w

 >30w

Ext. Dimensions.

 1360x780x2200

 1930x780x2200

 1360x780x2400

Inte. Dimensions.

 1200x610x680

 1734x610x680

 1200x610x680

Packing dimensions

 1490x880x2020

 2090x880x2020

 1490x880x2120

Operator

 1

 2

 1

Container load(sets)20’/40’/40’H

 6/16/16

 6/13/13

 6/16/16

Detachable Structure

  • Comply with human body working fundamental 10 degree tilt angle design ,so the operator will feel comfortable.
  • The bracket can be detached from the cabinet body ,&has optional bracket
  • The front board can be detached & washed ,the flow motor & the filter can be maintained & changed at front ,don’t need to move the cabinet body.

Visual front Screen

  • Adopt safety ultraviolet ray intercepting glass, the height of the glass screen can be adjusted according to requirement , the sound & light alarm will work when exceeding the safe height.
  • Patent technology balancer suspension system ,safe & reliable.

Inner cabinet

  • Adopting 304 stainless steel ,left right &back in wall formed together ,arc angle filter ensuring everywhere in clean
  • Left, right, back & bottom of working area have negative pressure pathway
  • Whole body forming work table adopts pallet structure ,so it is easy to detached &washed.
  • Equipped safe anti- explosion ,anti –splash power socket, water & cocket.
  • Vertical laminar flow negative pressure ,air curtain type isolation design ,this ensuring the operator safe ,avoiding cross infection, complying with the criteria of YY 0569 – 2005II biological safety cabinet
  • Innovated air flow isolation technology avoids leaking out from the seam of the front screen.

Ultra high Efficient filter system

  • The inflowing system adopts ULPA high efficient is more than 99.999% has filter lifespan display function.
  • Has filter real time alarm function.
  • Button Definition 1: [Blower Fan] air –inbreathing blower fan switch.
  • Button Defination 2: [light sorce] inner cabinet fluorescent lamp switch.
  • Button Defination3 : [Ultra violet light] inner cabinet starillizing Ultra violet light switch It can only operate when blower fan fluorescentlamp shut, 7 the front window is closed.
  • Button Definition 4 : [outlet] inner cabinet electric outlet switch , which can be controlled independently.
  • Button Definition 5:[set] Button for advanced setup of BSC, through which can setup time switch - on & switch – off Ultra violet light & other advanced adjustment etc.
  • Button Definition 6: add, subtract & overturn button ;,through which can add &substract the advanced setup data after setup button taking effect, alsothought which can check the operation state operation time,etc of the BSC.
  • Button Definition 7: [stop] sound ala5rming clkose button .through which can stop sound alarming after it beings, but not for the light alarming].
  • Basic function &operation display Lattice LC display is adopted ,& it should be 4 pages in normal state.

Displaying data in the screen

  • Displaying exhaust value(m3/h).
  • The velocity of air laminar flow(m/s).
  • Counter for exhaust fan.
  • Counter for blower.

Safety control system

  • Alarm for low air exhaust value.
  • Alarm for low air velocity of down laminar flow.
  • Alarm for fault of exhaust fan.
  • Alarm for closing condition of visible window.
  • When the visiable window is opened , the UV light will be closed automatically.
  • The blower will be off automatically if the exhaust fan happens some trouble. The exhaust fan will increase his rotate speed automatically in order to keep the working space in negative pressure inside cabinet in case something wrong happens with the blower.
  • Microprocessor will counhteract thegradually increased resistance in filter. It will keep air inflow & downflow in normal condition under any condition.

Standard compliance

  • En 12469 type tested (exceeds requirements for classII micro biological safety cabinet)
  • Air cleanliness :ISOM14664.1 class 3,IEST-G-CC1001,iest g-g cc1002 &other equivalent air cleanliness requirements
  • Fater performance ;IEST – RP –CC034,1 IEST –RP-CC007,1,IEST RPCC007, 1IEST-RP- CC001,3& EN1822.
  • Electrical safety:IEC61010- 1/EN 61010-1/UL3101-/CSA C 22.2 NO. 1010.1-92
>> Top      
  >> Quote Enquiry
   
Copyright © 2011 Bioline Technologies. All Rights Reserved . Website Designed and Developed by Manomay Informatics