Construction :

This unit has double walled insulated PUF modular panels which can be easily assembled at site. Interior is made of Stainless Steel and Exterior is either made of Mild Steel finished with powder coating or Stainless Steel. The unit has full-length inner glass door and outside metal door with magnetic gasket and lock. The unit is provided with perforated Stainless Steel trays. Forced air circulation for uniform temperature.

 

Temperature Range : 20°C to 60°C Accuracy : ± 0.2°C
Humidity Range : 40% RH to 95% RH Accuracy : ±2% RH
Temperature Uniformity : ±1°C Humidity Uniformity : ± 3% RH
  • Temperature & Humidity Suitable for 25 °C& 60% RH, 40 °C & 75% RH, 30 °C & 65% RH
  • Specially designed chambers to carry out stability studies at low humidity conditions such as 25°C & 40% RH, 40°C & 25% RH NMT, 30°C & 35% RH

Intelligent Control System :

  The controlling system having is PLC Base and PC communication

Heating System :

  Long lasting stainless steel tubular heaters with s.s. fins.

Humidity System :

Humidity is by steam injection. A humidifier tank is fitted with two nos of heaters. One heater works as a stand by in case the regular heater fails. A water reservoir tank is connected to the boiler tank. Two boiler tanks are fitted with magnetic float switch and float valve. Magnetic float switch is provided for the safety of boiler as it facilitates in cutting off the heater supply in case of low level of water.

Sensor :

Rotronic make temperature and humidity transmitter 4-20mA with very low drift per year. Temperature in degree Celsius and Humidity in %RH with 0.1°C and 0.1%RH

Cooling System :

Hermitically sealed compressor coupled with evaporation coil and condenser, safe guarded by time delay circuit. CFC free refrigerant.

Alarms :

  Audio and visual alarms are generated for temperature / humidity variation.

Safety :

  This unit is provided with safety devices for temperature and humidity over shoot in case of malfunction.

The unit works on 230 Volts AC and 50Hz mains supply.

Selection Guide :

Models

Capacity

Internal Dimension

ExternalDimension

Trays

Size

Exterior M.S. Powder Coated Interior S.S.

Interior & Exterior S.S

Cuft.

Litres

HxWxD (Mtr.)

HxWxD (Mtr.)

Nos.

Mtr.

NEC 2190RI

NEC 2190RSI

190

5400

2.00 x 1.36 x 2.00

2.12 x 1.48 x 2.12

24

0.865 x 0.35

NEC 2230RI

NEC 2230RSI

230

6400

2.40 x 1.36 x 2.00

2.52 x 1.48 x 2.12

32

0.865 x 0.35

NEC 2280RI

NEC 2280RSI

280

8000

2.00 x 2.00 x 2.00

2.12 x 2.12 x 2.12

24

0.865 x 0.60

NEC 2340RI

NEC 2340RSI

340

9600

2.40 x 2.00 x 2.00

2.52 x 2.12 x 2.12

32

0.865 x 0.60

NEC 2530RI

NEC 2530RSI

530

15000

2.40 x 2.50 x 2.50

2.52 x 2.62 x 2.62

48

0.725 x 0.80

NEC 2640RI

NEC 2640RSI

640

18000

2.40 x 2.50 x 3.00

2.52 x 2.62 x 3.12

48

0.90 x 0.80

     