   Stability / Environmental Test Chambers
 
 
Stability Chambers
 

 

   

Click To Enlarge

Construction :

The unit is a double walled chamber, with glass wool / PUF insulation. Interior is made of Stainless Steeland Exterior is either made of Mild Steel finished in powder coating paint (powder coating on both sides of the mild steel) or Stainless Steel. The unit has full-length inner glass door and outside metal door with magnetic gasket and lock. The unit is provided with perforated Stainless Steel trays. Forcedair circulation for uniform temperature. PU wheels for easy move ability.

 

Temperature Range : 20°C to 60°C Accuracy : ± 0.2°C
Humidity Range : 40% RH to 95% RH Accuracy : ±2% RH
Temperature Uniformity : ±1°C Humidity Uniformity : ± 3% RH
  • Temperature & Humidity Suitable for 25 °C& 60% RH, 40 °C & 75% RH, 30 °C & 65% RH
  • Specially designed chambers to carry out stability studies at low humidity conditions such as 25°C & 40% RH, 40°C & 25% RH NMT, 30°C & 35% RH

  Intelligent Control System :

  The controlling system having is PLC Base and PC communication on Ethernet

  Heating System :

  Long lasting stainless steel tubular heaters with s.s. fins.

  Humidity System :

  Humidity is by steam injection. A humidifier tank is fitted with two nos of heaters. One heater works as a stand by in case   the regular heater fails. A water reservoir tank is connected to the boiler tank. Two boiler tanks are fitted with magnetic   float switch and float valve. Magnetic float switch is provided for the safety of boiler as it facilitates in cutting off the heater   supply in case of low level of water.

  Sensor :

  Rotronic make temperature and humidity transmitter 4-20mA used for measurement. Temperature in degree Celsius   and Humidity in %RH with 0.1°C and 0.1%RH resolution.

  Cooling System :

  Hermitically sealed compressor coupled with evaporation coil and condenser, safe guarded by time delay circuit. CFC   free refrigerant.

  Alarms :

  Audio and visual alarms are generated for temperature / humidity variation.

  Safety :

  This unit is provided with safety devices for temperature and humidity over shoot in case of malfunction.

  The unit works on 230 Volts AC and 50Hz mains supply.

  Selection Guide :

Models Capacity Internal Dimension External  Dimension Weight (Kg) Tray
Exterior M.S. Exterior S.S Cuft. Litres HxWxD (mm) HxWxD (mm) Eqp Shp Nos (mm)
NEC 208RT10I NEC 208RT10SI 8 200 600 x 600 x 600 1150 x 760 x 1045 200 275 2 560 x 560
NEC 212RT10I NEC 212RT10SI 12 324 900 x 600 x 600 1450 x 760 x 1045 250 325 3 560 x 560
NEC 216RT10I NEC 216RT10SI 16 430 1200 x 600 x 600 1795 x 760 x 1095 275 350 4 560 x 560
NEC 221RT10I NEC 221RT10SI 21 600 1200 x 700 x 700 1795 x 860 x 1195 300 400 4 660 x 660
NEC 228RT10I NEC 228RT10SI 28 800 1200 x 800 x 800 1795 x 960 x 1295 325 425 4 760 x 760
NEC 234RT10I NEC 234RT10SI 34 1000 1500 x 800 x 800 2095 x 960 x 1295 350 450 5 760 x 760

 

     