Construction

This unit is double walled chamber. Interior made of stainless steel and Exterior is either mild Steel finished with powder coating or stainless steel. Glass wool/PUF insulation between both the wall is provided. Full-length inner glass door and outside metal door with magnetic gasket & lock. Forced air circulation for uniform temperature. One Stainless Steel perforated tray is provided. The tray can be placed at various heights to accommodate the change in sample height. The purpose of doing so is to vary the exposure intensity to reduce the test duration. PU wheels for easy move ability.

 

Illumination
Chamber is illuminated using 4nos of flourescent tube light to produce visible light (measure in lux). A one no. Near UV light of wavelength 365nm (measured in watt/sq. Meter) are fitted on topside of the chamber.

Intelligent control system
Temperature Controller with Ethernet Communication

Cooling system  
Hermitically sealed compressor coupled with evaporation coil and condenser, safe guarded by time delay circuit. CFC free refrigerant.

Safety
A Safety thermostat to switch off the tube lights if temperature overshoots. Door switch to switch off the UV light when door is opened.

The unit works on 230 Volts AC and 50Hz mains supply.  
Selection guide for photostability chamber

 Temperature Range : 10°C to 40°C

 Accuracy : ± 0.5°C

 Temperature Uniformity : ±1°C


Models

Capacity

Internal Dimension

External Dimension

Weight (Kg)

Tray

Exterior Powder Coated Steel or S.S.

Exterior & Interior S.S.

Cuft

Ltrs.

Hxwxd (mm)

Hxwxd (mm)

Eqp

Shp

Nos.

(in mm)

NEC 104RTSPI

NEC 104RTSPSI

4

100

450 x 450 x 480

875 x 700 x 645

80

155

1

410 x 440

NEC 108RSPI

NEC 108RSPSI

8

227

600 x 630 x 600

1285 x 790 x 895

200

275

1

580 x 550

Eqp - Equipment
Shp
- Shipping

Election guide for photostability chamber with humidity

 Temperature Range : 10°C to 40°C

 Accuracy : ± 0.2°C

 Humidity Range : 40% RH to 80% RH

 Accuracy : ±2% RH

 Temperature Uniformity : ±1°C

 Humidity Uniformity : ± 3% RH

 

Models

Capacity

Internal Dimension

External Dimension

Weight (Kg)

Trays

Tray Size

Exterior M.S. & Interior S.S

Exterior & Interior S.S

Cuft

Ltrs.

HxWxD (mm)

HxWxD (mm)

Eqp

Shp

Nos.

(in mm)

 NEC 208RHPI

NEC 208RHPSI

8

227

600 x 630 x 600

1285 x 790 x 895

200

275

1

580 x 550


  Optionals

  • A Calibrated Lux-Meter & UV Meter